(3617) 38 mm Spec-Caps®

Shallow, thin-walled aluminum cap for reinforcing XRFpellets. Commonly used in the production of pressed power sample disks for XRF but also used for OES and other analytical techniques. Forms the bottom and sides of the finished pellet. 38 mm wide x 9 mm deep. Produces pellets 40 mm x5 mm. Sold in bags of 100. Features.

قرأ أكثر

(3577) 31 mm Micro X-CELL®

6.3 mm window is centered in standard 31 mm sample holder. Only requires 0.5 mL of sample. Can be run with open back, sealed window back, or with Micro-porous Film. For hazardous or sensitive samples, top can be fitted with a standard 7 x 13 mm serum bottle closure for injection, purging, or sample isolation. Made of contaminate-free polyethylene.

قرأ أكثر

SPEX™ SamplePrep Dual Freezer/Mill 115 V/60 Hz

SPEX™ SamplePrep Dual Freezer/Mill 115 V/60 Hz. The 6875D Freezer/Mill is a high-throughput, dual chamber cryogenic grinder that chills samples in liquid nitrogen that …

قرأ أكثر

OPERATING MANUAL

4.4.2 Setting the Timer. When power is switched on, the timer will first display: SPEX SamplePrep 8000 Series MIXER/MILL. The timer will then display the default timer setting of five minutes (5:00). Assuming a grinding vial is clamped into the mill and the lid is down, pressing START will initiate a run of 5 minutes.

قرأ أكثر

HG-600 Geno/Grinder® 2010

Spex SamplePrep is now part of Cole-Parmer • Enables increased throughput, improved extraction efficiency and reproducibility • Designed for rapid cell disruption, cell lysis and tissue homogenization through bead beating • Ideal tool for QuEChERS method The Geno/Grinder is a high-throughput plant and animal tissue homogenizer and cell lyser.

قرأ أكثر

(2253-PC-48) 50 mL Polycarbonate Vials, 48 pack

Polycarbonate round-bottomed centrifuge tube vial with screw-on polyethylene cap. The nominal outer diameter measures 1 1/8 in x 4½ in long (29 mm x 114.3 mm). Holds two 7/16 in (11 mm) stainless steel grinding balls (# 2156 ). Grinding load per vial 1-10 g. Not recommended for liquids or wet mixing. Sold in package of 48.

قرأ أكثر

Cole-Parmer | Sampleprep

Application Notes. Our library of application notes can help you find the most suitable products and methods for your application. You can search for this information by Product Type, Sample Type, Application or by Technique. Feel free to …

قرأ أكثر

14 Edition SPEX SamplePrep HANDBOOK

sampleprep@spex Katanax 100-2500 Jean-Perrin Quebec, QC G2C 1X1 Canada Phone: +1 (418) 915-4848 info@katanax …

قرأ أكثر

SPEX CertiPrep

The Spex® Certiprep Genomic DNA Isolation Kits are optimized to work with the Genomax, Geno/Grinder, and GenoLyte and allow for fast and seamless isolation of DNA from a wide variety of animal tissues and cells, including mammalian, poultry, fish, and soft and tough plant tissue. The kit combines the use of chaotropic salts and detergents to ...

قرأ أكثر

8007

65 mL stainless steel grinding vial set, 2 1/4 in. (5.7 cm) diameter x 3 in. (7.62 cm) long. Grinding load 3–10 mL. Vial body and cap liner made of hardened 440C stainless steel. Set includes screw-on cap with O-ring, two 1/2 in. (12.7 mm), and four 1/4 in. (6.35 mm) stainless steel balls. Volume 65 mL; grinding load 3–10 mL; mixing load ...

قرأ أكثر

14 Edition SPEX SamplePrep HANDBOOK

sampleprep@spex Katanax 100-2500 Jean-Perrin Quebec, QC G2C 1X1 Canada Phone: +1 (418) 915-4848 info@katanax EUROPEAN DIVISION SPEX Europe 2 Dalston Gardens Stanmore, Middlesex HA7 1BQ United Kingdom Phone: +44 (0) 208 204 6656 Fax: +44 (0) 208 204 …

قرأ أكثر

SPEX SamplePrep Freezer/Mill®

The Basics. Samples are chilled at Liquid Nitrogen (LN) temperatures and ground using a Magnetically-Driven Impactor. No mechanical linkages or bearings to fail. Sealed …

قرأ أكثر

(3511) Kapton® Thin Film (Roll) | Cole-Parmer | Sampleprep

Often considered the closest thing to a "bombproof" XRF window film. Incredibly strong and heat resistant to over 300°C. Chemically impervious to almost anything except strong alkali solutions. Phosphate-based surface coating improves its handling characteristics. Box has a serrated edge for tearing thin window film to desired length.

قرأ أكثر

1600 MiniG

The HG-400 MiniG (part #1600), is the ideal solution for labs that want a compact yet powerful tissue homogenizer and cell lyser. It is equipped with an adjustable clamp that accommodates a full range of sample vials from 2 mL to 50 mL centrifuge tubes or up to two deep-well titer plates.

قرأ أكثر

HG-600 Geno/Grinder

The Geno/Grinder® (part # 2010) is a high-throughput plant & animal tissue homogenizer and cell lyser. It is equipped with an adjustable clamp that accommodates a full range of sample vials from 2mL to 50mL centrifuge tubes or up to six deep-well titer plates.

قرأ أكثر

SPEX CertiPrep

Our passion for science and dedication to the analytical community drives us to go above and beyond for you. We want to provide you with the customer experience you deserve and can rely on. We do this by …

قرأ أكثر

BM-200 Mixer/Mill ®, Mini (part #5120)

BM-200 Mixer/Mill. ®., Mini (part #5120) Ideal for pulverizing the toughest rocks, mineral, cement, and ceramics; rapidly reducing samples to analytical fineness; blending powders; and making emulsions. Finely grinding the sample increases the surface area to improve acid dissolution for ICP, and pellet pressing or fusion bead for XRF. Features.

قرأ أكثر

3621 Manual/Press | Cole-Parmer

3621 Manual/Press. Full-size 12-ton (10.9 metric ton) Carver® hydraulic laboratory pellet press that accepts 13 mm, 31 mm, 35 mm, and 40 mm pellet die sets. Manually controlled. Ideal for pressing sample pellets for XRF, IR, and other analytical techniques. CE Approved.

قرأ أكثر

(6801P) Large Stainless Steel Impactor | Cole-Parmer | Sampleprep

Call toll free (US) 1-855-GET-SPEX or (732) 623-0465 for more information. FREE Handbook of Sample Preparation & Handling . Click here (6801P) Large Stainless Steel Impactor. ... Application notes and product literature may not be available for all SPEX SamplePrep accessories.

قرأ أكثر

(2304-400AW) Pre-Filled 2 mL tubes with 400 μm

Call toll free (US) 1-855-GET-SPEX or (732) 623-0465 for more information. FREE Handbook of Sample Preparation & Handling . Click here ... Application notes and product literature may not be available for all SPEX SamplePrep accessories.

قرأ أكثر

Mixer/Mill®

BM-400 Mixer/Mill® (part # 8000M) - High-Energy Ball Mill. High-energy ball mill that grinds up to 10 grams of sample. Wide selection of grinding and mixing vials available including hardened steel, stainless steel, tungsten carbide, alumina ceramic, zirconia ceramic, silicon nitride, agate, polystyrene, methacrylate, polystyrene, and polycarbonate.

قرأ أكثر

8200 Planetary Mill | Cole-Parmer

The Cole-Parmer BM-600 Planetary Mill (part number #8200) grinds samples with a mechanical motion, rotating the jar in one direction while the platform (sun wheel) is rotated in the opposite direction. The mechanical milling is performed at a 2:1 ratio causing the container to rotate twice relative to every single rotation of the sun wheel.

قرأ أكثر

BM-400, BM-450 Mixer/Mill®

Spex SamplePrep is now part of Cole-Parmer Ordering Information Description Item Number BM-400 Mixer/Mill Single-Clamp, 115 VAC, 60 Hz 04578-12 BM-400 Mixer/Mill Single-Clamp, 230 VAC, 50 Hz 04578-13 ... Contact us today at sampleprep@antylia for details. 4773S.2 BM-400, BM-450 Mixer/Mill® ...

قرأ أكثر

(8505) Alumina Ceramic Grinding Container | Cole-Parmer

Steel lid and aluminum dish are lined with alumina ceramic plates, puck is solid alumina ceramic. 6.3 in. diameter x 3.2 in. high, 11 lbs. (15.2 cm x 8 cm, 5 kg). Nominal volume 170 mL, recommended grinding load 15-40 mL. Includes puck, dish with O-ring gasket, and lid. Ideal for grinding extremely hard, brittle samples in the 8500 Shatterbox ...

قرأ أكثر

(6761) Small Poly-Vial Set | Cole-Parmer

Call toll free (US) 1-855-GET-SPEX or (732) 623-0465 for more information. FREE Handbook of Sample Preparation & Handling . Click here (6761) Small Poly-Vial Set. ... Application notes and product literature may not be available for all …

قرأ أكثر

8000M MIXER/MILL

The SPEX SamplePrep 8000-series Mixer/Mills are efficient, compact laboratory mills capable of pulverizing samples in the 10-gram range. Functionally …

قرأ أكثر

6875D Freezer/Mill

The CG-500 Freezer/Mill® (part #6875D), is a high-throughput, dual chamber, cryogenic grinder. It accommodates samples in the 0.1 gram to 200 gram range (100 per grinding chamber).

قرأ أكثر

8200 Planetary Mill | Cole-Parmer | Sampleprep

Features. Specifications. Accessories. Documents. Brochures. Ergonomic design makes loading a grinding jar into the mill easy. Programmable touch screen interface capable …

قرأ أكثر

(2310) 2 mL Reinforced Tube | Cole-Parmer

Call toll free (US) 1-855-GET-SPEX or (732) 623-0465 for more information. FREE Handbook of Sample Preparation & Handling . Click here ... Specifications. Application notes and product literature may not …

قرأ أكثر

SPEX SamplePrep 8000M MIXER/MILL Operating Manual

View and Download SPEX SamplePrep 8000M MIXER/MILL operating manual online. 8000M MIXER/MILL laboratory equipment pdf manual download.

قرأ أكثر